Screen Reader Access Skip to Main Content Font Size   Increase Font size Normal Font Decrease Font size
Indian Railway main logo
Search :
Find us on Facebook   Find us on Twitter Find us on Youtube View Content in Hindi
National Emblem of India

About Us

NR H.Q.

Divisions

Passenger & Freight services

News & Recruitment Info

Tenders

Contact Us



 
Bookmark Mail this page Print this page
QUICK LINKS
Duty list of Officers & Key Supervisors

 

1.0ORGANISATIONAL SETUP

 

1.1Gazetted:

 

There are three JAG/SG Officers comprising of Sr.DSTE/C, Sr.DSTE/I & Sr.DSTE/II and assisted by four Senior Scale Officers and five Assistant Scale Officers.

 

Out of this team of officers, three senior scale officers viz. DSTE/Sig/HQ, DSTE/Tele/HQ and DSTE/I/HQ are headquartered at Divisional Office. Two senior scale officers headquartered at Faridabad and Hazrat Nizamuddin and five Junior Scale Officers headquartered at Panipat, New Delhi, Delhi, Meerut Cantt, and Rohtak.

 

1.2Non-Gazetted:

There are thirteen maintenance units with stores in the field, responsible for proper upkeep of signaling gears of the division. Each unit is headed by a Sr. Supervisor. Similarly, there are four maintenance units with stores in the field, responsible for proper upkeep of telecom gears of the division. Each unit is headed by a Sr. Supervisor.

 

 

Category

Sanctioned Strength

On Roll

Vacancy

Group ‘C’ (Signal)

885

700

185

Group ‘D’ (Signal)

881

646

235

Group ‘C’ (Telecom)

492

445

47

Group ‘D’ (Telecom)

209

135

74

Total

2467

1926

541

 

 

2.0INFRASTRUCTURE

 

2.1Signaling:

 

2.1.1

Item

Nos.

Remarks

Total No. of Interlocked stations

159

 

SSI/EI

66

 

RRI/PI (RST)

93

 

Total Automatic Signaling Section in RKM

173

32 Auto Section

Total No. of Intermediate Block Signaling Section

08

GZB-GUH (with BPAC), GGN-GHH (HASSDAC with BPAC)

KIP-RE, ROK-SMF, SPZ-KRZ, JHI-BZO, JHL-BRZ& ASE-SPZ (with SGE & HASSDAC)

Total nos. of LC gates

362

 

Total No. of Interlocked L-xings

228

(ELB=135& MLB=93)

Total No. of Interlocked L-Xing with SLB

228

 

Total No. of non-interlocked manned L-xings with communication facility

134

 

 

 

 

2.1.2Type of Signaling

 

ROUTE

SECTION

TYPE OF INTERLOCKING

STD. OF INTERLOCKING

NO. OF STATIONS

TYPE OF SIGNALLING

A

NDLS - PWL

RRI

III

5

MACLS

IIR

6

MACLS

TKJ(EX) - CYZ

EI

IIIR

1

MACLS

RRI

III

2

MACLS

IIR

2

MACLS

B

DEE - RE(EX)

EI

II

2

MACLS

III

8

MACLS

IIR

1

MACLS

PI

III

1

MACLS

GZB(EX) - SRE(EX)

EI

IIR

14

MACLS

PI

III

3

MACLS

IIR

2

MACLS

RRI

IIR

1

MACLS

SZM - UMB(EX)

EI

III

3

MACLS

IIIR

8

MACLS

PI

III

1

MACLS

IIIR

7

MACLS

IIR

1

MACLS

RRI

III

3

MACLS

IIIR

3

MACLS

IIR

2

MACLS

C

DLI - DSA - 'A' PNL

RRI

III

2

MACLS

DLI(EX) - BTI(EX)

PI

IIR

1

MACLS

RRI

III

1

MACLS

HNZM(EX) - DBSI(EX)

EI

III

2

MACLS

PI

III

1

MACLS

NDLS - PWL

PI

IIR

1

MACLS

D

ABO(EX) - RE(EX)

PI

IIR

5

MACLS

DEE - RE(EX)

PI

II

1

MACLS

DLI - DSA - 'A' PNL

PI

IIR

1

MACLS

DLI(EX) - BTI(EX)

EI

IIR

2

MACLS

PI

III

3

MACLS

IIR

27

MACLS

RRI

IIR

4

MACLS

DSA(EX) - SMQL - TPZ(EX)

EI

II

10

MACLS

IIR

1

MACLS

PI

III

1

MACLS

JHI(EX) - PNP(EX)

EI

II

2

MACLS

III

1

MACLS

IIR

1

MACLS

PI

III

1

MACLS

IIR

1

MACLS

JHI(EX)-SNP(EX)

PI

IIR

3

MACLS

NRW(EX) - KKDE(EX)

EI

IIR

3

MACLS

ROK-Hansi

EI

II

3

MACLS

IIR

2

MACLS

ROK(EX) - PNP(EX)

EI

II

1

MACLS

IIR

1

MACLS

ROK(EX) - SNP(EX)

PI

IIR

1

MACLS

 

 

2.1.3 Type of Block working

 

Route

 

Section

Type of Block working

No. of Block Sections

 

 

‘A’

NDLS-TKJ

Automatic signaling section (6 Lines)

01

TKJ-HNZM

Automatic signaling section (4 Lines)

01

HNZM-OKA

Automatic signaling section

01

OKA-JNC

Automatic signaling section (4 Lines)

08

JNC-PWL

Automatic signaling section (UP & DN M/L)

06

TKJ - CYZ

Automatic signaling section (Double Line)

04

GZB-CYZ

Continuous track circuiting 3rd line

01

 

 

 

‘B’

DLI-SZM

Continuous track circuiting (Double Line)

01

SZM-SNP

Automatic signaling section (Double Line)

06

SNP-SLKN

Block Instrument (Double Line) with SSDAC

01

SLKN-PNP

Block Instrument (Double Line) with HASSDAC

06

PNP-GRA

Automatic signaling section (Double Line)

02

GRA-BZK

HASSDAC with UFSBI (double line)

03

BZK-MOY

Block Instrument (Double Line) with HASSDAC

09

 

GZB-GUH

IBS (with BPAC)

01

GUH-MUD

BPAC (Double Line)

01

MUD-MDNR

Block Instrument (Double Line) with Dual SSDAC

01

MDNR-MTC

BPAC (Double Line)

03

MTC-PQY

Block Instrument (Double Line) with Dual SSDAC

02

PQY-KAT

Block Instrument (Double Line) with HASSDAC

03

KAT- MOZ

Block Instrument (Double Line) with Dual SSDAC

03

MOZ-SRE

Block Instrument (Double Line) with HASSDAC

07

 

DEE-PTNR

HASSDAC (Twin single Line)

02

HASSDAC (UP line)

01

PTNR(MG)-DEC

HASSDAC with SGE type Block instrument

02

North Line, South Line - HASSDAC

01

DEC-PM

Block Instrument (Double Line) with SSDAC

01

PM-GGN

BPAC (Double Line)

02

GHH-JSKA

Block Instrument (Double Line) with HASSDAC

02

JSKA-KIP

UFSBI with HASSDAC

03

KIP-RE

IBS (SGE with HASSDAC)

01

 

 

 

 

‘C’

 

 

HNZM-LPNR

Automatic signaling section (DC TC) (D/L)

01

OKA-LPNR

Continuous track circuiting (D/L)

01

LPNR-DSJ

Automatic signaling section D/D (MSDAC & AFTC) (D/L)

01

DSJ – BRSQ

Automatic signaling section (MSDAC) (D/L)

01

BRSQ-PTNR

Automatic signaling section D/D (MSDAC & AFTC) (D/L)

01

PTNR(BG)-DBSI(SSB)

HASSDAC (Double Line)

01

DBSI-ANDI

BPAC (Double Line)

01

DBSI-DLI

Continuous track circuiting (D/L)

02

DLI-APNL

Twin Single line Automatic signaling section (DC TC)

03

APNL-BPNL

Continuous track circuiting (S/L)

01

JNC-FDB (3rd & 4th Line)

UFSBI with HASSDAC

02

FDB-FDN (3rd & 4th Line)

UFSBI with HASSDAC

02

FDN – PYA (3rd & 4th Line)

UFSBI with HASSDAC

04

PYA-PWL (3rd & 4th Line)

UFSBI with HASSDAC

04

D

DBSI-SSB

Continuous track circuiting

01

NNO-ASE

Block Instrument (Double Line) with HASSDAC

04

ASE-KRZ

IBS (SGE with HASSDAC)

02

KRZ-ABO

Block Instrument (Double Line) with SSDAC

01

ABO-ROK

Block Instrument (Double Line) with Dual SSDAC

01

ROK-SMF

IBS (SGE with HASSDAC)

01

SMF-KIU

Block Instrument (Double Line) with SSDAC

05

KIU-BSPH

Block Instrument (Double Line)

01

BSPH-JHI

Block Instrument (Double Line) with SSDAC

01

JHI-BZO

IBS (SGE with HASSDAC)

01

BZO-GSO

Block Instrument (Double Line) with Dual SSDAC

02

GSO-DTN

Block Instrument (Double Line) with SSDAC

03

DTN-TUN

Block Instrument (Double Line) with HASSDAC

01

TUN-JHL

Block Instrument (Double Line) with SSDAC

02

JHL-BRZ

IBS (SGE with HASSDAC)

01

BRZ-BTI

Block Instrument (Double Line) with SSDAC

10

DSA-NO

UFSBI (Single Line) with SSDAC

01

NO-KQL

UFSBI (Single Line) with HASSDAC

05

KQL-SMQL

UFSBI (Single Line) with HASSDAC

01

SMQL-HID

UFSBI (Single Line) with dual SSDAC

01

HID-THBN

UFSBI (Single Line) with HASSDAC

02

NNX-TPZ

UFSBI (Single Line) with HASSDAC

03

 

ROK-GHNA

NTI (Ball)

01

GHNA-NLH

UFSBI (Single Line) with HASSDAC

02

NLH-PNP

UFSBI (Single Line) with HASSDAC

01

 

ROK-HANSI

UFSBI (Single Line) with HASSDAC

05

 

JHI-JCY

UFSBI (Single Line) with HASSDAC

01

JCY-PPDE

UFSBI (Single Line) with HASSDAC

01

PPDE-PKDE

UFSBI (Single Line) with HASSDAC

01

PKDE-MLDE

UFSBI (Single Line) with HASSDAC

02

MLDE-BHUL

UFSBI (Single Line) with HASSDAC

01

BHUL-KURN

BPAC (Single Line)

01

PNP-KURN

Block Instrument (Double Line) with SSDAC

01

 

NRW-KKDE

UFSBI (Single Line) with HASSDAC

04

 

ABO (ex)-RE (ex)

Token less (Daido) with SSDAC

05

 

PPDE(Ex)-SNP(Ex)

NTI (Ball)

04

2.2 Telecom:

Sr. No.

No. of Items

Total

1

PA System

155 Stns.

2

Digital Clocks

150 Stns.

3

Coach Display System

18 Stns.

4

Train Display System

17 Stns.

5

CCTV

27 Stns.

6

BSNL/FCT Phones

161 Stns.

7

CNL Phone

161 Stns.

8

Telephone Exchange

31 Nos.

9

25Watt VHF set

195 Stns.

10

STM

187 Nos.

11

MUX

185 Nos.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.3Staff in terms of DESU - SIGNAL

 

DESU over Delhi Division

 

DESU

2023-24

485677.77

2024-25

493215.10

% Increase

1.5%

 

 

 

 

 

 

 

Signal staff per thousand DESU (493215.10)

 

Sanction Staff

Sanction Staff per thousand DESU

On roll staff

On roll Staff per thousand DESU

1766

3.58

1351

2.73

 

 

 

 

 

 

2.4Staff in terms of DETU - TELECOM

 

DETU over Delhi Division

 

DETU

2023-24

703189.25

2024-25

708833.43

% Increase

0.79%

 

 

 

 

 

 

 

Telecom staff per thousand DETU (708833.43)

 

Sanction Staff

Sanction Staff per thousand DETU

On roll staff

On roll Staff per thousand DETU

701

0.98

582

0.82

 

 

 

 

 

 





Source : Northern Railways / Indian Railways Portal CMS Team Last Reviewed : 27-08-2025  


  Admin Login | Site Map | Contact Us | RTI | Disclaimer | Terms & Conditions | Privacy Policy Valid CSS! Valid XHTML 1.0 Strict

© 2016  All Rights Reserved.

This is the Portal of Indian Railways, developed with an objective to enable a single window access to information and services being provided by the various Indian Railways entities. The content in this Portal is the result of a collaborative effort of various Indian Railways Entities and Departments Maintained by CRIS, Ministry of Railways, Government of India.