|
Sr. No |
TYPE PLAN NO |
DESCRIPTION
|
|
1 |
JOINT STATION BUILDING FOR FLAG STATION |
|
|
2 |
GOODS SHED WITH OFFICE |
|
|
3 |
OPEN GOODS SHED (PROVISIONAL) |
|
|
OPEN GOODS SHED DETAIL OF JOISTS (PROVISIONAL) |
||
|
4 |
SIGNAL CABIN (CAPACITY=10 TO 20 LEVER) |
|
|
SIGNAL CABIN (CAPACITY=10 TO 20 LEVER) DETAILS (PROVISIONAL) |
||
|
5 |
STRONG ROOM |
|
|
6 |
TYPE DESIGN FOR 48 BED RUNNING ROOM |
|
|
DETAILS OF DOORS & WINDOW |
||
|
DETAILS OF FIRE PLACE |
||
|
DETAILS OF LOCKER & SURAHI REACESS |
||
|
DETAILS OF RCC MAIN STAIRCASE |
||
|
DETAIL OF RCC SLAB, BEAMS, LINTELS & CHAJJAS |
||
|
7 |
TYPE DESIGN FOR 12 BED & 18 BED RUNNING ROOMS |
|
|
RCC DETAILS LINTELS & LINTELS-CUM-CHAJJAS |
||
|
DETAILS OF RCC SLAB, BEAM |
||
|
8 |
WAITING SHED AT HALT STATIONS |
|
|
9 |
STATION BUILDING FOR CROSSING STATIONS D&D KEY SIDING STATION |
|
|
STATION BUILDING FOR CROSSING STATIONS D&D KEY SIDING STATION (SHOWING RCC DETAIL OF CANOPY CHAJJA LINTEL COLUMN) |
||
|
10 |
BOOKING OFFICE AT HALT STATION |
|
|
BOOKING OFFICE AT HALT STATION (SHOWING RCC DETAIL OF SLAB, LINTEL & CHAJJA) |
||
|
11 |
PWIS OR IOWS OFFICE WITH GODOWN & WORKSHOP |
|
|
PWIS OR IOWS OFFICE WITH GODOWN & WORKSHOP RCC DETAILS |
||
|
PWIS OR IOWS OFFICE WITH GODOWN & WORKSHOP DETAILS XPM FIXING IN WORKSHOP |
||
|
12 |
WORKSHOP & RUNNING SHED TYPICAL DESIGN FOR NON-ATTENDANT TYPE DRINKING WATER INSTALLATION |
|
|
WORKSHOP & RUNNING SHED TYPICAL DESIGN FOR NON-ATTENDANT TYPE DRINKING WATER INSTALLATION.DETAILS OF RCC TANK |
||
|
13 |
WORKSHOP & RUNNING SHED TYPICAL DESIGN FOR SANITARY BLOCK (FOR 100 USERS) |
|
|
WORKSHOP & RUNNING SHED TYPICAL DESIGN FOR SANITARY BLOCK (FOR 100 USERS) DETAILS OF DOORS WINDOWS |
||
|
WORKSHOP & RUNNING SHED TYPICAL DESIGN FOR SANITARY BLOCK (FOR 100 USERS) DETAILS OF RCC SLAB LINTELS |
||
|
14 |
WORKSHOP & RUNNING SHED TYPICAL DESIGN FOR URINAL BLOCK (FOR 200 USERS) |
|
|
WORKSHOP & RUNNING SHED TYPICAL DESIGN FOR URINAL BLOCK (FOR 200 USERS).DETAILS OF RCC SLAB LINTELS |
||
|
15 |
WORKSHOP & RUNNING SHED TYPICAL DESIGN FOR DRINKING WATER BOOTH (WITH COOLER OR WATER POSTS) |
|
|
WORKSHOP & RUNNING SHED TYPICAL DESIGN FOR DRINKING WATER BOOTH (WITH COOLER OR WATER POSTS) - DETAILS OF RCC WORK |
||
|
16 |
DESIGN OF WARNING BOARD FOR DRIVER & FIREMAN |
|
|
17 |
HEALTH UNIT GRADE I, II & III |
|
|
HEALTH UNIT GRADE I, II & III - DETAILS OF DOORS & WINDOW |
||
|
HEALTH UNIT GRADE I, II & III - DETAILS OF RCC SHELVES (MEDICAL STORE) |
||
|
HEALTH UNIT GRADE I, II & III - DETAILS OF RCC BEAMS, LINTELS & CANOPY |
||
|
18 |
SIGNAL CABIN FROM 14 TO 49 LEVER WITHOUT BALCONY (1935 TYPE) PROVISIONAL |
|
|
SIGNAL CABIN FROM 14 TO 49 LEVER WITHOUT BALCONY (1935 TYPE) PROVISIONAL - RCC DETAIL OF STAIR CASE |
||
|
19 |
SIGNAL CABIN FROM 60 LEVER WITH BALCONY (PROVISIONAL) |
|
|
20 |
SIGNAL CABIN FROM 150 LEVER S&F TYPE WITH BALCONY |
|
|
21 |
STANDARD PLAN OF SANITARY BLOCK (FLUSH TYPE LATRINES) |
|
|
22 |
TYPE PLAN RUNNING ROOM 48 BEDS |
|
|
DETAILS OF DOOS & WINDOW |
||
|
DETAILS CUPBOARD CHULLAH & RAILING |
||
|
RCC DETAILS ROOF, SLAB, BEAM & STAIRCASE |
||
|
23 |
TYPE PLAN TEA STALL ON OPEN PLATFORM |
|
|
24 |
TYPE PLAN TEA STALL ON OPEN PLATFORM - RCC DETAILS |
|
|
25 |
K.V. RAILWAY TYPE DRG. FOR VENDOR SHOP (ON PLATFORM) |
|
|
26 |
STANDARD PLAN OF SMALL RECREATION CLUB |
|
|
STANDARD PLAN OF SMALL RECREATION CLUB - RCC DETAILS |
||
|
27 |
STANDARD PLAN OF REST SHELTER FOR PORTERS (PLAN, ELEVATION & SECTION) |
|
|
STANDARD PLAN OF REST SHELTER FOR PORTERS (RCC DETAILS) |
||
|
28 |
PREFABRICATED PUMP HOUSE (PLAN, SECTION & ELECVATION) |
|
|
DETAILS OF COMPONENTS & FIXTURES ETC. |
||
|
29 |
STANDARD PLAN REST ROOM FOR RPF SAINIKS (PLAN, SECTION & ELEVATION) |
|
|
30 |
STANDARD PLAN REST ROOM FOR RPF SAINIKS (PLAN DETAILS) |
|
|
31 |
TYPE PLAN OPEN TEA STALL (UNDER COVERED SHED) ON RAILWAY PLAFORM |
|
|
32 |
STANDARD PLAN FOR DIESEL GENERATOR SET ROOM OF DIFFERENT CAPACITIES UPTO 400 KVA RCC DETAILS |
|
|
33 |
STANDARD PLAN 2X750KVA CAPACIY ELECTRICAL SUB STATION WITH AND WITHOUT DG SET ROOM, GENERAL ARRANGEMENTS |
|
|
STANDARD PLAN 2X750KVA CAPACIY ELECTRICAL SUB STATION WITH AND WITHOUT DG SET ROOM (RCC DETAILS) |
||
|
34 |
STANDARD PLAN 2X750KVA CAPACIY ELECTRICAL SUB STATION WITH AND WITHOUT DG SET ROOM, GENERAL ARRANGEMENTS |
|
|
STANDARD PLAN 2X750KVA CAPACIY ELECTRICAL SUB STATION WITH AND WITHOUT DG SET ROOM (RCC DETAILS) |
||
|
35 |
STANDARD PLAN WAY SIDE STATION (TYPE-C) |
|
|
STANDARD PLAN WAY SIDE STATION (TYPE-C) - RCC DETAILS |
||
|
36 |
STANDARD PLAN WAY SIDE STATION (TYPE-A) |
|
|
STANDARD PLAN WAY SIDE STATION (TYPE-A) - RCC DETAILS |
||
|
37 |
STANDARD PLAN WAY SIDE STATION (TYPE-B) |
|
|
STANDARD PLAN WAY SIDE STATION (TYPE-B) - RCC DETAILS |
||
|
38 |
STANDARD PLAN WAY SIDE STATION (TYPE-D) |
|
|
39 |
TYPE PLAN OF HALT STATION PLAN & SECTION |
|
|
TYPE PLAN OF HALT STATION (RCC DETAILS) |
||
|
40 |
STANDARD PLAN OF COMPUTERISED RESERVATION CENTRE (FOR 6 COUNTERS) PLAN, COUNTER DETAILS, PLINTH & LINTEL BEAMS |
|
|
STANDARD PLAN OF COMPUTERISED RESERVATION CENTRE (FOR 6 COUNTERS RESERVATION SECTION |
||
|
41 |
STANDARD PLAN OF DUTY HUT DURING FOG |
|
|
42 |
STANDARD PLAN OF DUTY BUNK FOR MANNED LEVELX-ING ( FORMATION DEPTH UPTO 2M ) |
|
|
43 |
STANDARD PLAN OF DUTY BUNK FOR MANNED LEVELX-ING ( FORMATION HT. MORE THAN 2M AND UPTO 4M ) |
|
|
STANDARD PLAN OF DUTY BUNK FOR MANNED LEVEL X-ING RCC DETAILS OF SLAB COLUMN FLOOR AND TOP BEAM |
||
|
44 |
(This Type Plan superseded by Type Plan No. O-99/2021) |
STANDARD PLAN BUILDING FOR SIGNAL EQUIPMENT FOR ¾ LINE CENTRAL PI STATION. GROUND FLOOR PLAN, ELAVATION AND SECTION. |
|
45 |
GUIDANCE PLAN FOR DISPLAYING YEAR OF CONSTRUCTION ON ALL BUILDINGS AND STRUCTURES. |
|
|
46 |
GUIDANCE PLAN FOR NUMBERING OF DRINKING WATER BOOTH AND TAPS ON PLATFORMS. |
|
|
47
48
49
50
51
52
53
54 |
O-106/2023-R1 |
GUIDANCE PLAN FOR DISPLAYING DATE OF WHITE WASH AND PAINTING ON ALL BUILDINGS AND STRUCTURES.
TYPE PLAN FOR S&T BUILDING AT INDEPENDENT INTERLOCKED L-XING GATE/IBS.
TYPE PLAN FOR RCC DETAIL OF PLINTH BEAM, LINTEL BEAM, SLAB AND CHAJJA GANG REST ROOM WITH TOOL ROOM
TYPE PLAN FOR S&T SERVICE BUILDING
TYPE PLANS FOR LAYOUT OF NSG - 3, 4, 5 & 6POWDER TOILET FOR DIVYANGJANS
STANDARD TYPE PLAN FOR MINIMUM ESSENTIAL AMENITIES (MEA) AND ACCESSIBILITY PLAN FOR DIVYANGJAN
TYPICAL BUILDING PLAN FOR S&T AUTOHUT FOR AUTOMAITC BLOCK SIGNALLING AND OTHER MODERN SIGNALLING
|

Accessibility Controls